parcelsfolder.portlandmaine.gov - /Files/215/215 B002/Building Permits/2017-01387 Alterations - Commercial/1. Original Plans/


[To Parent Directory]

A00.010 PARTITION TYPE DETAILS
A00.010A UL DETAILS
A00.011 DOOR FRAME AND HARDWARE SCHEDULE - HO2
A00.011 DOOR FRAME AND HARDWARE SCHEDULE
A00.012 DOOR AND GLAZING DETAILS
A00.013 DOOR AND GLASING DETAILS
A00.013 DOOR AND GLAZING DETAILS
A00.020 FINISH LEGEND
A00.021 FINISH LEGEND
A01.100E DEMOLITION PLAN - LEVEL 00 EAST
A01.101E DEMOLITION PLAN - LEVEL 01 EAST
A01.101W DEMOLITION PLAN - LEVEL 01 WEST
A01.102E DEMOLITION PLAN - LEVEL 02EAST
A01.102W DEMOLITION PLAN - LEVEL 02 WEST
A01.200 DEMOLITION RCP - OVERALL LEVEL 00-HO2
A01.201 DEMOLITION RCP - OVERALL LEVEL 01-HO2
A01.202 DEMOLITION RCP - OVERALL LEVEL 02-HO2
A01.300 MONUMENTAL STAIR - DEMO PLANS AND RCP
A01.400 ALTERNATE #1 - DEMO PLANS
A02.100E CONSTRUCTION PLAN - LEVEL 00 EAST
A02.101E CONSTRUCTION PLAN - LEVEL 01 EAST - HO2
A02.101W CONSTRUCTION PLAN - LEVEL 01 WEST-HO2
A02.102E CONSTRUCTION PLAN - LEVEL 02 EAST-HO2
A02.102W CONSTRUCTION PLAN - LEVEL 02 WEST-HO2
A02.200E REFLECTED CEILING PLAN - LEVEL00 EAST-HO2
A02.201E REFLECTED CEILING PLAN - LEVEL 01 EAST HO2
A02.201W REFLECTED CEILING PLAN - LEVEL 01 WEST-HO2
A02.202E REFLECTED CEILING PLAN - LEVEL 02 EAST-HO2
A02.202W REFLECTED CEILING PLAN - LEVEL 02 WEST-HO2
A03.100 MONUMENTAL STAIR - ENLARGED PLANS
A03.101 MONUMENTAL STAIR - SECTIONS
A03.201 ENLARGED PLANS DETAILS ELEVATIONS - ELEVATOR #2
A03.300 ENLARGED PLANS AND INTERIOR ELEVATIONS - TOILET-HO2
A03.301 ALTERNATE #1 - ENLARGED PLANS-EXISTING RESTROOMS LEVEL 01
A03.302 ALTERNATE #1 - ENLARGED PLANS-EXISTING RESTROOMS LEVEL 02
A03.303 ALTERNATE #1 - INTERIOR ELEVATIONS-EXISTING TOILETS
A03.311 ALTERNATE #2 - ENLARGED PLANS-EXISTING EGRESS STAIRS
A04.100 ENLARGED EXTERIOR ELEVATIONS
A06.201 CEILING DETAILS
A07.100 ENLARGED PLANS AND INTERIOR ELEVATIONS-PUBLIC SQUARE
A07.101 ENLARGED PLANS AND INTERIOR ELEVATIONS-PANTRY
A07.102 ENLARGED PLANS AND INTERIOR ELEVATIONS-PRINT COPY EAST
A07.103 ENLARGED PLANS AND INTERIOR ELEVATIONS-PRINT COPY CENTRAL
A07.104 ENLARGED PLANS AND INTERIOR ELEVATIONS-PRINT COPY WEST
A07.105 ENLARGED PLANS AND INTERIOR ELEVATIONS - MEETING ROOMS
A07.106 ENLARGED PLANS AND INTERIOR ELEVATIONS - MEETING ROOMS
A07.107 ENLARGED PLANS AND INTERIOR ELEVATIONS - SECURITY ROOM
A07.108 ENLARGED PLANS - LEVAL 02-PRINT AND COPY WEST
A07.109 ENLARGED PLANS AND INTERIOR ELEVATIONS-COLLABORATION
A07.110 ENLARGED PLANS AND INTERIOR ELEVATIONS-LEVEL 01-HO2
A07.120 ENLARGED PLANS AND INTERIOR ELEVATIONS - VENDING
A07.130 ENLARGED PLANS AND INTERIOR ELEVATIONS - COMMUNITY TABLE
A08.100 DETAILS - PERIMETER PLAN DETAILS
A08.200 MISC DETAILS
A08.500 DETAILS - MILLWORK
A08.501 DETAILS - MILLWORK-PUBLIC SQUARE
AV.0DL.00 AUDIOVISUAL DRAWING LOG
AV.0KY.01E AUDIOVISUAL KEY PLAN
AV.0KY.01W AUDIOVISUAL KEY PLAN
AV.0KY.02E AUDIOVISUAL KEY PLAN
AV.0KY.02W AUDIOVISUAL KEY PLAN
AV.101.00 AUDIOVISUAL SCOPE OF RESPONSIBILITIES
AV.102.00 AUDIOVISUAL NOTES
AV.201.1E AUDIOVISUAL PLAN - FACILITY
AV.201.1W AUDIOVISUAL PLAN - FACILITY
AV.201.2E AUDIOVISUAL PLAN - FACILITY
AV.201.2W AUDIOVISUAL PLAN - FACILITY
AV.202.1E AUDIOVISUAL PLAN - ELECTRICAL
AV.202.1W AUDIOVISUAL PLAN - ELECTRICAL
AV.202.2E AUDIOVISUAL PLAN - ELECTRICAL
AV.202.2W AUDIOVISUAL PLAN - ELECTRICAL
AV.301.00 AUDIOVISUAL ELEVATIONS & SECTIONS
E1.001 LEGEND NOTES & DETAILS ELECTRICAL
E1.002 SPECIFICATIONS-ELECTRICAL
E1.003 SPECS (CONT) - ELECTRICAL
E1.004 LIGHT FIXTURE SCHEDULE & LIGHTING CONTROL DETAILS
E1.100E GROUND FLOOR PLAN (EAST) - ELECTRICAL
E1.101E 1ST FLOOR PLAN (EAST) - ELECTRICAL
E1.101W 1ST FLOOR PLAN (WEST) - ELECTRICAL
E1.102E 2ND FLOOR PLAN (EAST) - ELECTRICAL
E1.102W 2ND FLOOR PLAN (WEST) - ELECTRICAL
E1.200E GROUND FLOOR PLAN (EAST) - LIGHTING
E1.201E 1ST FLOOR PLAN (EAST) - LIGHTING
E1.201W 1ST FLOOR PLAN (WEST) - LIGHTING
E1.202E 2ND FLOOR PLAN (EAST) - LIGHTING
E1.202W 2ND FLOOR PLAN (WEST) - LIGHTING
E1.300E GROUND FLOOR PLAN (EAST) - FIRE ALARM
E1.301E 1ST FLOOR PLAN (EAST) - FIRE ALARM
E1.301W 1ST FLOOR PLAN (WEST) - FIRE ALARM
E1.302E 2ND FLOOR PLAN (EAST) - FIRE ALARM
E1.302W 2ND FLOOR PLAN (WEST) - FIRE ALARM
E1.400 PARTIAL PLANS (ELEC ROOMS) - ELECTRICAL
E1.500 RISER DIAGRAM - ELECTRICAL
E1.610 PANEL SCHEDULES - ELECTRICAL
E1.611 PANEL SCHEDULES - ELECTRICAL
E1.612 PANEL SCHEDULES - ELECTRICAL
E1.620 PANEL SCHEDULES - ELECTRICAL
E1.621 PANEL SCHEDULES - ELECTRICAL
E1.622 PANEL SCHEDULES - ELECTRICAL
ED1.100 GROUND LEVEL PLAN - ELECTRICAL DEMO
ED1.101 1ST FLOOR PLAN - ELECTRICAL DEMO
ED1.102 2ND FLOOR PLAN - ELECTRICAL DEMO
F1.100E GROUND FLOOR PLAN (EAST) - FIRE PROTECTION
F1.101E 1ST FLOOR PLAN (EAST) - FIRE
F1.101W 1ST FLOOR PLAN (WEST) - FIRE PROTECTION
F1.102E 2ND FLOOR PLAN (EAST) - FIRE PROTECTION
F1.102W 2ND FLOOR PLAN (WEST) - FIRE PROTECTION
G00.000 COVER SHEET (CONSTRUCTION)
G00.000 COVER SHEET (DEMO)
G00.001 DRAWING INDES PROJECT INFORMATION (CONSTRUCTION)
G00.001 DRAWING INDEX PROJECT INFORMATION
G00.002 ADA INFORMATION & TYPICAL MOUNTING HEIGHTS (CONST)
G00.002 ADA INFORMATION & TYPICAL MOUNTING HEIGHTS
G00.003 GRAPHIC SYMBOLS AND ABBREVIATIONS (CONST)
G00.003 GRAPHIC SYMBOLS AND ABBREVIATIONS
G00.004 CODE SIGNAGE
I02.100E FINISH PLAN - LEVEL 00 EAST-HO2 (2)
I02.100E FINISH PLAN - LEVEL 00 EAST-HO2
I02.101E FINISH PLAN - LEVEL 01 EAST-HO2 (2)
I02.101E FINISH PLAN - LEVEL 01 EAST-HO2
I02.101W FINISH PLAN - LEVEL 01 WEST-HO2 (2)
I02.101W FINISH PLAN - LEVEL 01 WEST-HO2
I02.102E FINISH PLAN - LEVEL 02 EAST-HO2 (2)
I02.102E FINISH PLAN - LEVEL 02 EAST-HO2
I02.102W FINISH PLAN-LEVEL 02 WEST-HO2 (2)
I02.102W FINISH PLAN-LEVEL 02 WEST-HO2
I02.201 FURNITURE PLAN - OVERALL LEVEL 01-HO2 (2)
I02.201 FURNITURE PLAN - OVERALL LEVEL 01-HO2
I02.202 FURNITURE PLAN - OVERALL LEVEL 02-HO2 (2)
I02.202 FURNITURE PLAN - OVERALL LEVEL 02-HO2
LS02.101 LIFE SAFETY PLAN - LEVEL 01-HO2 (CONST)
LS02.101 LIFE SAFETY PLAN - LEVEL 01-HO2
LS02.102 LIFE SAFETY PLAN - LEVEL 02-HO2 (CONST)
LS02.102 LIFE SAFETY PLAN - LEVEL 02-HO2
M1.001 SPECIFICATIONS - HVAC
M1.002 SPECIFICATIONS - HVAC
M1.003 SPECIFICATIONS NOTES AND SCHEDULES - HVAC
M1.004 DETAILS AND OUTSIDE AIR TABLES - HVAC
M1.005 FIRE STOP DETAILS - HVAC
M1.100E GROUND FLOOR PLAN (EAST) - HVAC
M1.101E 1ST FLOOR PLAN (EAST) - HVAC
M1.101W 1ST FLOOR PLAN (WEST) - HVAC
M1.102E 2ND FLOOR PLAN (EAST) - HVAC
M1.102W 2ND FLOOR PLAN (WEST) - HVAC
MD1.100 GROUND LEVEL PLAN - HVAC AND PLUMBING DEMO
MD1.101 1ST FLOOR PLAN - HVAC AND PLUMBING DEMO
MD1.102 2ND FLOOR PLAN - HVAC AND PLUMBING DEMO
P1.001 SPECIFICATIONS - PLUMBING
P1.002 SPECIFICATIONS NOTES AND DETAILS - PLUMBING
P1.003 FIRE STOP DETAILS - PLUMBING
P1.101E 1ST FLOOR PLAN (EAST) - PLUMBING
P1.101W 1ST FLOOR PLAN (WEST) - PLUMBING
P1.102E 2ND FLOOR PLAN (EAST) - PLUMBING
P14.102W 2ND FLOOR PLAN (WEST) - PLUMBING
S02.000 GENERAL NOTES
S02.101 LEVEL 01 PARTIAL FRAMING PLAN
S02.102 LEVEL 02 PARTIAL FRAMING PLAN
S02.400 FRAMING SECTIONS AND DETAILS